• Slc license server. How to configure SLC to work on multiple computers. Key computer parameters

    In this manual, we will look at how to configure SLK to work on several computers. The example will consider working on two computers connected to a single network. Two hardware protection keys are used: for the main workstation, red, and for the additional workstation, yellow.

    Note: Instructions for working with software protection keys can be viewed


    Setting up SLK

      First of all, you need to install the licensing system itself (SLK), detailed instructions can be found at the link. SLK needs to be installed only on the main computer, on which the protection keys will be located.

      After installing SLK, install both keys on the main computer and launch the SLK console. The console can be opened through the Start menu:


      Note: the console should open in the browser. If it does not open automatically, you need to open any browser on your computer and enter http://127.0.0.1:9099 in the address bar.

      If the keys are functional and everything is installed correctly, they will be displayed in the console:


      For each key, its type and number of licenses are written.

      In this case, there is a main key for 1 workplace and an additional key for 5 workplaces.

      IMPORTANT: the additional key will not work without the main one. If you install only this on your computer, the console will display a warning that a master key is required:



      If the keys are not displayed in the console, you need to check the following:


      If the device does not work correctly, you need to try updating the driver:


    1. We launch the 1C program.

      When running the program on an additional workstation, the following message may appear:


      You need to follow the link “Licensing system parameters”. In the window that opens, indicate the name or IP address of the computer on which the protection keys are installed, as well as the network port. The computer name can only be specified if it is written in Latin letters. Next, click “Check license”; if the key is found, a message will appear:


      After this, close the settings window using the “Save and close” button.

      The next time you open the program, the settings will be saved.

      Note: If the check fails, the firewall or antivirus may be blocking port 9099 or another one being used. You should check if this port is open. If a port is closed, you can either disable your antivirus and firewall, or configure rules for that port.

      Note: You can find out which port is used in the SLK console:

      What to do if SLK “does not see” the security key

      If, after the steps described above, you still cannot configure the operation of the SLK, you need to create a request to our technical support by mail [email protected]. To quickly analyze the issue, it is advisable to indicate:

      1. Full name and release of the program.

        Operating mode in 1C: file, client-server, web server. Where to see the operating mode, see

        SLK version, information on licenses used:

        hardware or software keys;

        how many workplaces are licensed for?

    2. Detailed description of the question:

      wording of displayed messages, if any (attach screenshots);

      whether the security keys are lit. If not, have you tried to check their functionality on other ports or computers;

      whether the keys are displayed in the SLK console;

      Which computer can’t be configured to work on: the main one or the secondary ones.

    If you already have SLK installed on your computer and you need to install a new version, you can do this in several ways:

    1. Remove the old version of SLK and install the new one;

    2. Launch the distribution kit for installing the new version of SLK immediately.

    Let's consider both options.

    1. First, let's remove the old version of SLK, for this:

    • Let's close all 1C applications and remove the hardware protection keys.
    • Go to the folder C:\Program Files (x86)\1C\Licence 2.0\Uninstall and run the file “Uninstall.exe”:
    • This will open a window for removing the licensing system; click the “Continue” button:

    • A message confirming deletion will appear, click the “Delete” button:

    • After finishing removing the SLK, click the “Exit” button:

    Now we can start installing the new version of SLK 2.1.6.420:

    • Download the licensing system distribution and unzip it to any folder:

    • Let's run the file “LicenceServer-2.1.6.420-Setup.exe”. This will open the licensing system installation window, click on the “Next” button:

    • Make sure that all additional tasks that need to be completed are checked and click the “Install” button:



    Note: The server console can be launched later, for example, through the menu “Start – All programs – SLK – SLK Server Console”.

    2. The process of installing a new version of SLK can be started immediately, without uninstalling the previous version, for this:


    At the same time, a message appears that there is already an installed version of SLK on the computer and it is proposed to update it to the new version. Click the “Next” button:

    Check all the boxes and click the “Install” button. During the installation process, you will need to update the security key driver, click the “Update” button:

    • During installation, the message “Install software for this device?” will appear, click on the “Install” button:

    After completing the installation process, close the window:

    As a result, the SLK was updated.

    System for licensing and protecting configurations of the 1C:Enterprise 8 platform, version 2.0

    Installing a software key

    General provisions. 1

    . 2

    . 2

    Launching the SLK server console. 2

    Entering a PIN code. 3

    Choosing an installation method. 4

    Automatic installation. 4

    . 5

    . 7

    Installation by phone. 8

    . 9

    . 9

    General provisions

    Software protection key is a SLK component designed to access protected objects and control the number of workstations based on the number of licenses specified in the key.

    The protection key can be of the following types:

    · Basic. Included in the main product delivery. A key that can be installed on any computer.

    · Additional. Included as part of the delivery of an additional (single-user or multi-user) license. A key installed additionally to increase the number of licenses. Additional keys do not work without the primary key and must be installed on a computer that already has the primary security key installed.

    The SLK software key is generated based on the configuration of the computer on which the SLK server is installed and is a file on the hard drive (location of software key files with m. Location of software keys). To install a software key, you need a pin code or activation code, which is a sequence of 20 digits, for example:

    30

    The PIN code must be indicated in the document included in the configuration delivery. This can be a paper form or a text file containing the PIN code itself and the characteristics of the security key (type, number of licenses, validity period, etc.).

    The PIN code can only be used once. If you change the computer configuration, the key may become inoperative. To restore functionality, it is possible to obtain a limited number (no more than 2) backup PIN codes. To obtain a backup PIN code, you must contact the 1C-Rating company and indicate the serial number of the key that has lost its functionality and the reason for the failure.

    Opening hours of the SLK Licensing Center

    Processing of requests for automatic activation and requests through the website is carried out around the clock, seven days a week (on weekends, routine maintenance may occur, during which automatic activation may not be available).

    Processing of requests by e-mail and telephone is carried out from 10.00 to 18.00 Moscow time on weekdays (according to the schedule of Moscow enterprises).

    How to install a software key

    To install the software key, start the SLK server:

    Start Menu – SLK 2.0 – SLK Server Console

    font-size:12.0pt;font-family:Calibri">In the main console window on the command bar, select the command " Install software key...» or press the function keyF6 on the keyboard.

    font-size:12.0pt;font-family:Calibri">The software key installation dialog will open:

    font-size:12.0pt;font-family:Calibri">By default, the dialog prompts you to enter an activation pin code and create a request to the SLK Licensing Center (steps to set up a response from the SLK Licensing Center, received on electronic media or by telephone, are described below in section Installing a response from the SLK Licensing Center).

    The SLK software key activation pincode is a sequence of 20 digits in which a series of protection keys and the serial number of the key are encoded, for example:

    30

    To create a request, enter your PIN code and click the “Next” button.

    font-size:12.0pt;font-family:Calibri">The program will check the correctness of the entered data and proceed to the next step - sending the request to the SLK Licensing Center.

    Select the method for submitting the request to the SLK Licensing Center. The following options for sending a request are possible:

    X-NONE">Automatic installation

    If your computer is connected to the Internet, this method is most preferable. In this case, the system will independently complete a request to the SLK Licensing Center and install the key on your computer.

    font-size:12.0pt;font-family:Calibri">To complete the request and install the key, click the “Install” button. If the request is processed successfully, a message will be displayed and the key will be shown in the main console window.

    font-size:12.0pt;font-family:Calibri">If you need to install another software key, click the “Next” button.

    Installation on electronic media

    This method is used if your computer is not connected to the Internet, but you have the opportunity to work with email and the Internet from another computer.

    font-size:12.0pt; font-family:Calibri">Submitting a request to the SLK Licensing Center is possible in two ways:

    § by email katran @1 c. ru

    Copy the request to the clipboard and paste it into the body of the letter (or save the request to a file that you attach to the letter). Send a letter to the SLK Licensing Center at: katran @1 c. ru. The response letter will contain data for activating the key. DFor steps to install the received response, see the section Installing a response from the SLK Licensing Center.

    § on the website http ://prom. licensecenter. ru

    Open the site in any Internet browser http ://prom. licensecenter. ru. Copy the request to the clipboard, paste it into the input field on the site and click the “Process” button.

    The processing result will be displayed on the same page under the input field:

    Copy the answer to the clipboard and save it to a text file. For a brief description of the steps to install a response from the SLK Licensing Center, see paragraph Installing a response from the SLK Licensing Center.

    Installing a response from the SLK Licensing Center

    To install the response received from the SLK Licensing Center on electronic media, select the appropriate item in the software key installation dialog:

    Copy the received response from the SLK Licensing Center to the clipboard (or save it as a text file), load the response into the input field and click the “Install” button.

    If the installation is successful, a corresponding message will be displayed and the key will be shown in the main console window:


    Installation by phone

    This method is used as a last resort when it is not possible to work with the Internet and email.

    Call the phone number indicated in the document containing the PIN code and tell the operator of the SLK Licensing Center the set of numbers indicated in the dialogue, checking the checksum at the end of each line. Having verified the final checksum, click the “Next” button to proceed to receiving a response from the SLK Licensing Center.

    The operator will dictate a similar set of numbers that makes up the data for activating the software key. The numbers are entered line by line, checking the checksum at the end of each line. After verifying the final checksum, click the “Install” button to complete the installation.

    If the installation is successful, a message will be displayed and the key will be shown in the main console window.

    Key computer parameters

    The software key is generated based on the following parameters of the computer on which the SLK server is installed:

    § Hard drive

    § Motherboard

    § Processor

    If these components are changed, the software key may become inoperative. To restore functionality, re-installation will be required, for which it is possible to obtain a limited number of activation PIN codes (see General provisions).

    Location of software keys

    Physically, the software key is a file on the hard drive of the computer on which the SLK server is installed.

    The key files are located in the folder:

    < ProgamData>\1 C\ License\ Data\

    Where This is the shared program data folder.

    For Windows Vista and higher it could be the following path:

    C:\ProgramData\1C\Licence\Data\

    For Windows XP / 2003, respectively:

    C:\Documents and settings\All users\Application Data\1C\Licence\Data

    You can download SLK for a specific configuration version in the table below:


    In order to update the licensing system, follow these steps:

      Let's close all 1C applications and remove the hardware protection keys.

      Let's remove the old licensing system. To do this, go to the folder “C:\Program Files (x86)\1C\Licence 2.0\Uninstall” and run the file “Uninstall.exe”:

      This will open the licensing system removal window. Click on the “Continue” button:

      A message appears confirming the deletion. Check all the boxes and click on the “Delete” button:

      Let's wait for the removal process to complete and click on the "Exit" button:

      Download the 2.0 licensing system distribution and unzip it to any folder:

      The unpacked folder will contain the following files:

      Let's run the file "LicenceSetup.exe". This will open the licensing system 2.0 installation window, click on the “Continue” button:

      In the next window, check all the boxes. We will leave the folder in which the licensing system will be installed as default. Click the “Install” button:

      The installation program will issue a warning, click “Install”:

      The installation process will begin:

      During installation, the message “Do you want to install software for this device?” will appear, click on the “Install” button:

      Let's wait until the installation process is completed, check the box "Start the SLK server console when exiting the installation program" and click on the "Exit" button:

      The “Server Console” window will open. Let's plug the hardware security keys into the USB ports. In this case, all protection keys must be defined in the “SLK Server Console” window:

    Acquisition

    Distribution of products of the licensing and configuration protection system is carried out only by 1C franchise partners.

    Sequence of purchasing 1C:SLK system components

    "1C:SLK. Development kit" (article 2900001759540)

    "1C:SLK. Developer Kit" is an archive that consists of a security software component, documentation in electronic form and two evaluation single-user SLK software licenses with parameters for limiting the operation of the software key for 10 and 30 days.

    A trial version of the SLK development kit is provided for free. In trial mode, only those software licenses that are included in the delivery are available. To continue working with the system in full mode and order software licenses for the product, you must purchase “1C:SLK. Developer Kit” (item 2900001759540).

    1C:SLK. Software licenses (articles2900001759502, 2900001759519, 2900001759526)

    SLK software licenses are a digital-alphabetic activation code transmitted electronically for subsequent receipt of a license at the SLK Licensing Center. The software license is tied to the configuration of the user’s computer or to the hardware carrier of the SLK licenses.

    If the computer configuration is changed, the software license may become inoperative. To restore functionality, it is possible to obtain a limited number (no more than 2) backup codes. When all backup codes are used, a new license is purchased.

    The line of software licenses "1C:SLK" version 3 is backward compatible with "1C:SLK" version 2; There are no electronic software licenses for "1C:SLK" version 1.

    "1C:SLK. Hardware license carrier (USB) "(article 2900001759496)

    "1C:SLK. Hardware license carrier (USB)" (article 2900001759496) is a hardware device connected to the USB port of a computer and is an unactivated hardware key for "1C:SLK" version 3. Activation of the "Hardware license carrier" occurs by "binding "SLK software license, activated using an "activation code", for this device. In this case, the hardware media becomes a hardware configuration protection key that corresponds to the type and number of seats of the software license. In this case, the software license becomes inactive, and no duplication of jobs occurs.

    "1C:SLK. Hardware license media (USB)" is designed to work with "1C:SLK" version 3.

    "1C:SLK. Set of software licenses (PROMO, 100 pcs.)" (article 2900001765480)

    To conduct targeted promotions and free distribution of non-commercial versions of their own product among potential clients, the development partner can order "1C:SLK. Set of software licenses (PROMO, 100 pcs.)". The electronic delivery of the kit consists of a file containing 100 single-user software licenses (activation codes) for 30 days of operation of a specific series configuration belonging to that product developer.

    1C:SLK. Electronic hardware keys (items 2900001488099, 2900001488105, 2900001941044, 2900001488112)

    An electronic hardware key is a USB device prepared for a specific configuration and containing a license of a certain type.