• UPS monitoring and management. Software

    The UPS is connected to PC1 with a cable (RS232, USB or other), monitoring software is installed on PC1. PC1 is powered via a UPS. The UPS is monitored/controlled from PC1. If PC1 is connected to the network, remote notification (Email, etc.) is possible.

    PC is present or absent, GSM modem automatically send alarm SMS to cellular phone.
    There may or may not be a PC, the GSM modem automatically sends emergency SMS [network failure, low battery, etc.] to the cell phone.

    P5A) PC with SMS Server Software + GPRS Modem

    UPS monitoring system, PC, GPRS modem. A computer is required.

    Notes:

    • The SMS server program (SMS server manager) can be freely downloaded from the MEGATEC website, and it is also located on the included disk of the Megatec SNMP adapter (NetAgent).
    • It is recommended to use only the native GPRS modem supplied by the factory to avoid incompatibility.

    P6B) SNMP adapter BP505/506 + GPRS Modem

    UPS monitoring system, SNMP adapter BP50X, GPRS modem.

    • SNMP adapter BP505 (external, 3-port / External 3 Ports NetAgent II), GPRS Modem
    • SNMP adapter BP506 (internal, 3-port / Internal 3 Ports NetAgent II), GPRS Modem

    The computer may be missing. The system can work both in conjunction with a PC and without it:

    UPS --> 3 Ports NetAgent (BP505 or BP506) --> GPRS modem


    Appendix 1

    Options P5), P6) can also be used if there is a connection to local network(LAN).

    Addendum 2

    2.1) Example of a problem: for example, it is necessary to automatically send SMS messages when a UPS fails.

    Possible solutions:

    • The easiest way. A system (for example, a security system) with SMS sending is used, connected to the UPS via dry contacts (in most UPSs dry contacts are an option).
    • Based on standard or additional UPS monitoring, based on SNMP or other adapter.
    • SMS sending using standard software (for example, UPSman software, N-Power Evo UPS, SNMP adapter CS121, SMS Server Manager software, UPS, SNMP adapter DP522).

    Possible problems:

    • When sent via free servers SMS can be a problem.
    • When working with paid SMS distribution servers (device support servers automatic mailing SMS) there may be problems.
    • When broadcasting through a local “non-native” (third-party) radio modem, compatibility problems may arise.
    • Create your own bat file, which will give a command to send to a local “non-native” radio modem - possible but difficult.
    • Writing your own software that gives a command to send to a local “non-native” radio modem is possible but difficult.

    2.2) Sending SMS via E-Mail - this is the most common option (due to its simplicity and reliability compared to other options), since the main telephone operators This service was opened in Russia from 2009-2011. How it works: in the UPS monitoring software, in the E-Mail mailing section, you need to enter the address of the EMAIL server that converts E-Mail to SMS. Then the SMS goes as expected to the address you specified. telephone number. Payment is made using the SIM card of your phone. Do not confuse this service with a (server for) paid/free SMS distribution! All information regarding this service can be obtained from your telephone number/ mobile operator.

    Note: there are a large number of lists of servers on the Internet that supposedly perform these functions for free. IN present moment there is no reliable confirmation of their performance. Use only your mobile operator and its servers and instructions.

    Addendum 3

    PCs and laptops may not have an RS232 port (COM port). In this case, use a USB-card (optional) installed in the smart slot of the UPS or any USB-RS232 (COM) adapter, also called an adapter or converter. For example:

    • Controller ST-Lab U224 USB TO RS-232 COM SERIAL.
    • USB RS-232 Serial Adapter USB Serial Adapter Converter Prolific Chip (CABLEMAX).

    Addendum 4

    In all the options listed above, not only standard wired but also non-standard communication can also be used, for example, communication via power lines or demon wired connection(G, GSM, WIFI. Various Internet radio extension technologies can also be used: GHz technologies, operators of cellular, satellite, trunking and other radio communications, amateur radio HF, VHF and other radio communications, as well as specialized wired communications (communication via power lines etc.), and accordingly all the usual properties of the corresponding remote monitoring / control of the UPS are applied: sending E-Mail, SMS, notification / control via the network anywhere in the world from any device with access to the Internet or telephone and other network, 24/7 system dispatching and monitoring “Teleglobal Service” (GSM), etc. See. example below ( wireless internet UPS access):



    However, in order to avoid problems with radio networks, as well as if it is necessary to connect the UPS to the network at a point where there is no local network, incl. To send SMS, it is recommended to use the monitoring options given in P5, P6.

    Example of a "wireless Internet access to UPS" system
    4.1 Remote wireless access via HTTP protocol

    Radio access to the UPS SNMP adapter via a WEB browser is presented below.

    Notes:

    • The UPS is not shown in the figure. Test results remote access: Communication with the adapter via HTTP is normal.

    Modem-router model: manufacturer C-MOTECH Co., Ltd., model CNU680RUS (modem-router C-motech CNR680W).
    SNMP/HTTP adapter model: SNMP / HTTP adapter NetAgent DK522 Mini External DK522.

    System diagram:


    General view of the system (UPS not shown):

    4.2 Remote wireless access via SNMP protocol

    Remote wireless access via the SNMP protocol (radio access to the SNMP UPS adapter via an SNMP manager) is usually implemented only within the local closed network enterprises. Standard SNMP on a WAN is not usually used due to the relatively poor security of this protocol, even though more secure versions have become available. SNMP protocol. Also, the usual implementation of data exchange on the WAN via SNMP is complicated by the fact that most Internet providers block SNMP traffic (ports). However, there is an exception: SNMP can be used on a WAN if you use private network extension technologies. LAN networks- VPN, secure tunnels and other secure means of expanding the local internal closed network of an enterprise. In this case, SNMP-based monitoring is no different from regular SNMP monitoring inside a closed LAN network. In any case, wireless access can be used.

    Sources uninterruptible power supply– an excellent option for ensuring stable operation of household, corporate or office equipment. Various schemes constructions make it possible to create on their basis a flexible protection system for any type of equipment. But, like any electronic devices, they need effective management. For this purpose they were developed software to control the UPS. Programs for uninterruptible power supply systems allow you not only to monitor all system parameters, but also to calibrate them if necessary.


    Intelligent Power - a powerful tool for corporate use

    The first software tool from the company, with which you can manage one or more uninterruptible power supply systems -. This complex allows you to increase the efficiency of energy supply management. With its help, working even with entire data centers is greatly simplified. It can also be used to work with small corporate networks.

    The UPS control program is installed within a few minutes and does not require special skills from the operator. Devices that need to be managed will be detected automatically immediately after launching the application. Flexibility of equipment configuration is achieved through the use of network protocols, allowing you to manage the system from anywhere on the network via a web interface. For operator convenience, reports on device operation have been converted into text and graphic format. Most important points are highlighted automatically using color coding.

    There is also the opportunity to automate the management process as much as possible. Sending notifications by email facilitates quick decision-making by the operator in the event of an emergency situation. This UPS software allows you to create macros that will perform certain actions based on UPS indicators. Due to this negative impact network interference on expensive equipment will be significantly reduced. The main advantages of this software package include:

      Compatible with devices and sensors from different manufacturers; Opportunity correct operation with physical and virtual machines;

      Integration with major visualization platforms;

      Operator-friendly operating interface;

      Availability of an integrated SNMP driver.

    The Intelligent Power tool includes two other applications: Intelligent Power Manager and Intelligent Power Protector. They will be discussed in more detail below.

    Intelligent Power Manager - Complete set of statistics

    This UPS software greatly facilitates the work of operators whose task is to monitor multiple power protection systems at once. Software Intelligent Power Manager not only displays data on the status of all controlled equipment on one screen, but also provides notification of responsible persons about the occurrence of emergency situations.

    Automatic search for new versions and updates - another one useful feature this program for uninterruptible power supply systems. The application monitors the official website for new software versions, which allows you to increase the level of protection by reducing the likelihood of operator error during the installation of an improved version of the program.

    IN free version The package includes the ability to simultaneously work with ten devices. If you want to develop a more powerful protection system, you will need to purchase a license for the program, which provides for interaction with more than a hundred devices. Based on the above, we can highlight the following advantages of this program for UPS:

      Ability to monitor UPS and climate sensors;

      Minimum skills for maintenance complex systems security of energy supply;

      Convenient network structure that the operator can configure according to his wishes;

      Efficient management of devices, even if they are located remotely.

    Safely turn off power with Intelligent Power Protector

    Any uninterruptible power supply or UPS system has a finite operating time of offline mode. If mains power continues to be lost and the resource battery is not enough, then the Intelligent Power Protector UPS firmware will ensure a smooth shutdown of the UPS load. In this way, the safety of the data will be ensured, and the work process will not be interrupted incorrectly.

    The UPS can be controlled in several modes. The Intelligent Power Protector utility allows the operator to independently select not only the time delay for the operation, but also the condition under which the operation of the equipment will be completed. The user can set a mode in which the OS will be completely powered off, put into hibernation mode, or a predefined condition will be met.

    Modern UPS can provide stable work several units at once server equipment. If each of these devices has a software shutdown procedure running, then managing them becomes significantly more complicated. Programs for uninterruptible power supply systems of the Intelligent Power Protector series do an excellent job of this task. They enable the operator to monitor exactly what load is connected to each UPS, even devices are periodically changed or disconnected from the UPS output. For of this package The following advantages of the program can be identified:

      Supports communication with uninterruptible power supplies via USB, RS232 interface or network;

      Possibility of installation in automatic mode, does not require special skills;

      Support parallel circuit UPS operation and redundant power supplies;

      The UPS program provides the ability to smoothly shut down equipment during a long-term absence of supply voltage.

    The Energy Controller 2 program is designed to monitor the parameters of Uninterruptible Power Sources (UPS) and control the functions of these sources. Initially, Energy Controller was created to interact with the IPPON Back Power Pro 400 UPS, but later it turned out that the program works normally with all other IPPON UPS models (ippon.ru). And Energy Controller 2 also supports Mustek UPS, and some Sven and Inelt UPS models.

    Why can you use Energy Controller 2?

    First, Energy Controller 2 constantly monitors the health of your UPS battery. When utility power is lost, your computer is powered by this battery. Energy Controller 2 will put your operating system into sleep mode as soon as the UPS reports that the battery is completely discharged. Once power is restored, you can return to work as if nothing happened.

    Secondly, if you enable the so-called “standby mode”, then after the operating system is completed, Energy Controller 2 will disconnect the entire load from the UPS output. This is convenient if you need to turn off other devices along with the computer, for example, an ADSL modem or an audio system.

    In the evenings, I sometimes use the TV tuner to watch TV shows. When I get tired of seeing advertisements interspersed with movies, I press the “Power” button on the remote control remote control and fall asleep. You don't have to worry about turning off your computer, stereo system or lights - Energy Controller 2 will do everything on its own.

    Thirdly, Energy Controller 2 will save all UPS parameters into data logs - CSV files. These files can be viewed in Excel and the data stored in them can be used to quick construction graphs or diagrams.

    Fourthly, Energy Controller 2 will tell you how many minutes are left until it is completely discharged UPS battery if there is a network power supply failure. Energy Controller 2 can also display output power UPS (in Volt-Amps and Watts), as well as the current in the load circuit (in Amps). And these parameters are not displayed in any other IPPON UPS monitoring programs!

    Fifthly, Energy Controller 2 can report problems with power supply over the network (MSG command), by email, via SMS or Twitter"a!

    Fifthly, Energy Controller 2 can send a graphical representation of the current UPS parameters to the Picasa web album and post a link to this drawing on your microblog.

    Sixth, if you want, Energy Controller 2 will turn your computer on and off according to a schedule.

    Seventh, all functions of Energy Controller 2 are available in Windows 7. And on your desktop you can display a gadget that will show all the important parameters of your UPS. The new version of the "OSD panel" gadget differs from previous opportunity configure the gadget - i.e. change the font, its color and size, background color and transparency.

    Eighth, if you are annoyed beep UPS, you can turn on an alternative signal that will be played through the computer speakers.

    Ninth, Energy Controller 2 now sends notifications about power problems using the Jabber protocol (XMPP).

    Tenth, if you have an IPPON or Mustek UPS, then simply download the Energy Controller 2 distribution and try this program.

    Minimum System Requirements

    Announcing system requirements it should be said that Energy Controller 1.30 was based on libraries Visual Basic 6. Unfortunately, VB 6 is already hopelessly outdated, so when creating new version Energy Controller used Microsoft environment Visual Studio 2008. Part of the code was written in C#, part in VB.NET. The second version of Energy Controller was created almost from scratch, because the Visual Basic update wizard was unable to convert the VB6 code to VB.Net. This is probably due to the use of many imported Win 32 API functions.

    Platform. NET Framework 3.5 is good because it allows you to get simple and convenient access to many functions of the operating system. But importing functions from the Win 32 API sometimes reminded me of trying to scratch my left big toe behind my right ear. Choosing the .NET Framework as the runtime environment gives a lot to the software developer, but also increases system requirements. Alas.

    So, Energy Controller 2 was tested on Windows XP, Windows Vista(32 & 64 bit) and Windows 7 (32 & 64 bit).

    Most likely, Energy Controller 2 will also work in server operating systems starting from Windows 2003, but I did not divide the application into two parts: a service and a user interface. And this is exactly how, from a security point of view, an application for monitoring server UPSs should be designed. The author of Energy Controller 2 does not often have to visit server sites, so Energy Controller 2 is still not very suitable for server OSes.

    To prevent Energy Controller 2 from eating up a significant portion of your processor's power, I recommend a processor with clock frequency not less than one gigahertz.

    Applications based on the .NET Framework 3.5 typically take up a lot of memory space (RAM), and therefore the volume RAM your computer must have at least 512 megabytes. You also need at least one free USB port or COM.

    In Windows XP and Windows 2003, you must install .NET Framework 3.5 SP1 (232 MB) and if for some reason you cannot download this file, then look for it on DVDs, included with some magazines. For example, on the "Chip" magazine disk in the "Service" section.

    An important part of the uninterruptible power supply system is software that allows you to monitor the status UPS and events in the electrical grid. The software allows you to track a lot important parameters UPS and networks: power failure, increase and decrease in voltage, change in voltage frequency, transition of the UPS to battery power, operation of the UPS in bypass mode, condition and temperature of the UPS batteries, etc. The software also allows you to correctly shut down equipment and programs in the absence of an operator .

    In today's environment, a loss of power can result in the loss of critical data, costly downtime, and damage to computer and industrial equipment. Using appropriate monitoring and control software makes UPS V universal solution power quality problems. The software is an indispensable and fully integrated element of the system, increasing its performance and ensuring process protection. When a power failure occurs, the software takes a number of actions: notifies users, moves processes to a specific status, closes open files and communication channels and correctly stops unattended systems. When power is restored in the network, automatic start system and its return to normal operation

    UPSMAN™

    UPSMAN is free software that comes with your General Electric UPS. UPSMAN exchanges information with the UPS via serial port, USB port or network interface(SNMP card) to obtain status data and measure data. During normal operation UPS All data on the status of the UPS and the network is saved in a log file and can be viewed over the network.

    During a power outage, UPSMAN monitors the time battery life The UPS runs on battery power and initiates local or network shutdown of computers if necessary. UPSMAN can use optional software. The RCCMD client part allows you to correctly shut down computers and programs running on them.

    Available for stopping and starting various methods: “cold” start, soft start, network start. In addition, UPSMAN's customizable and nearly unlimited event processing capabilities allow you to pre-configure your system for automatic notification user: by notifying the user over the network, by email, by sending SMS messages or by sending an RCCMD signal to remote computer to execute a pre-configured command.

    UPS status data can be accessed via WEB server. It can be accessed through standard browser, but an optional SNMP card is required. UPSMAN supports the following UPS models: Match, VH Series, GT Series, LP11/31T, LP33, SG Series.

    (Software for monitoring and managing the UPS, shutting down the computer/server correctly, serial number- in the archive along with the program)

    (USB to Serial adapter driver: to connect a UPS that has only an RS-232 port to a computer that has only a USB)

    (Software for changing advanced UPS settings (no-load shutdown, automatic start of the UPS when voltage appears, setting the output voltage to 220/230/240 V, frequency 50/60 Hz, etc.)

    RCCMD client part (paid software, trial period 30 days)

    RCCMD is a common and widely used UPS client. This software allows you to shut down correctly large quantity computers. Supported by 25 different operating systems and works together with UPSMAN.

    (Client part of the software for automatic shutdown of servers ( paid program, which is installed directly on the server, includes a Trial key for 30 days))

    EP OS Shutdown System

    This software is designed for the GE EP Series UPS and has the same functionality as the UPSMAN software.

    EP Series EP OS Shutdown System